ABB Time Relays
Measuring and monitoring relays
Relay Boards
LOREM IPSUM
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Donec vitae tortor lobortis, suscipit elit vel, lobortis massa. Praesent id semper sem, non pellentesque ipsum. Ut in porta leo. Praesent ornare et urna et scelerisque.
LOREM IPSUM
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Donec vitae tortor lobortis, suscipit elit vel, lobortis massa. Praesent id semper sem, non pellentesque ipsum. Ut in porta leo. Praesent ornare et urna et scelerisque.
LOREM IPSUM
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Donec vitae tortor lobortis, suscipit elit vel, lobortis massa. Praesent id semper sem, non pellentesque ipsum. Ut in porta leo. Praesent ornare et urna et scelerisque.
| Image |
Ordering Code
|
output | timer function descrition | rated control supply voltage | time range | control input | Qty | Accessories | Enq |
|---|---|---|---|---|---|---|---|---|---|
|
CT-ERX.14 |
1 CO |
Time relay/ ON-delay |
240 VAC 50Hz | 24 V DC/AC 50Hz |
0.3 s to 30 h |
-- |
|
||
|
CT-AHX.14 |
1 CO |
Time relay/ OFF-delay |
240 VAC 50Hz | 24 V DC/AC 50Hz |
0.3 s to 30 h |
-- |
|
||
|
CT-SDX.25 |
1 NO + 1 NO |
Time relay/ star-delta |
240 VAC 50Hz | 24 V DC/AC 50Hz |
3 s to 120 s |
-- |
|
||
|
CT-MKC.31 |
Solid Sate |
ON-delay/ OFF-delay with auxiliary voltage/ Impulse-ON/ Impulse-OFF with auxiliary voltage/ Flasher starting with ON/ Flasher starting with OFF/ Pulse former |
12-240 V AC/DC |
7 (0.05 s-100 h) |
AVAILABLE |
|
||
|
CT-MFC.12 |
1C/O |
ON-delay/ OFF-delay with auxiliary voltage/ Impulse-ON/ Impulse-OFF with auxiliary voltage/ Flasher starting with ON/ Flasher starting with OFF/ Pulse former |
24-240 V AC 24-48 V DC |
7(0.05 s-100 h) |
AVAILABLE |
|
||
|
CT-MFC.21 |
2C/O |
ON-delay/ OFF-delay with auxiliary voltage/ Impulse-ON/ Impulse-OFF with auxiliary voltage/ Flasher starting with ON/ Flasher starting with OFF/ Pulse former |
12-240 V AC/DC |
7(0.05 s-100 h) |
AVAILABLE |
|
||
|
CT-ARC.12 |
1C/O |
OFF-delay without aux. voltage (True OFF-delay)/True Impulse-OFF |
24-240 V AC / 24-48 V DC |
7(0.05 s-100 h) |
-- |
|
||
|
CT-ERC.12 |
1C/O |
ON-delay |
24-240 V AC / 24-48 V DC |
7(0.05 s-100 h) |
-- |
|
||
|
CT-ERC.22 |
2C/O |
ON-delay |
24-240 V AC / 24-48 V DC |
7(0.05 s-100 h) |
-- |
|
||
|
CT-AHC.12 |
1C/O |
OFF-delay |
24-240 V AC / 24-48 V DC |
7(0.05 s-100 h) |
-- |
|
||
|
CT-AHC.22 |
2C/O |
OFF-delay |
24-240 V AC / 24-48 V DC |
7(0.05 s-100 h) |
-- |
|
||
|
CT-VWC.12 |
1C/O |
Impulse-ON |
24-240 V AC / 24-48 V DC |
7(0.05 s-100 h) |
AVAILABLE |
|
||
|
CT-EBC.12 |
1C/O |
Flasher starting with ON/ Flasher starting with OFF |
24-240 V AC / 24-48 V DC |
7(0.05 s-100 h) |
AVAILABLE |
|
||
|
CT-TGC.12 |
1C/O |
Pulse generator/ON and OFF times adjustable independently: 2 x 7 time ranges 0.05 s - 100 h |
24-240 V AC / 24-48 V DC |
2x7(0.05 s-100 h) |
-- |
|
||
|
CT-TGC.22 |
2C/O |
Pulse generator/ON and OFF times adjustable independently: 2 x 7 time ranges 0.05 s - 100 h |
24-240 V AC / 24-48 V DC |
2x7(0.05 s-100 h) |
-- |
|
||
|
CT-SDC.22 |
2N/O |
Star-delta changeover/Transition time 50 ms fixed |
24-240 V AC / 24-48 V DC |
2x7(0.05 s-100 h) |
AVAILABLE |
|
||
|
CT-SAC.22 |
2N/O |
Star-delta changeover/Transition time adjustable |
24-240 V AC / 24-48 V DC |
2x7(0.05 s-100 h) |
AVAILABLE |
|
||
|
CT-MFS.21S |
-- |
-- |
24-240 V AC/DC |
10 (0.05 s- 300 h) |
-- |
|
||
|
CT-ERS.22S |
-- |
ON-delay (accumulative) with 2 c/o |
24-48 V DC/ 24-240 V AC |
10 (0.05 s- 300 h) |
-- |
|